Rack Distribution & Monitoring (ePDU)
Enclosed Power Distribution Units (ePDU's) from Eaton offer many flexible ways to distribute power within your rack enclosure to your end equipment. All ePDU's are built with industrial-grade materials and offer features distinguish them from a “power strip” for your mission-critical backup power equipment. With a wide verity of inputs, outputs, power ranges, mounting options, and other features, there is most likely a product that fits your needs. Customized ePDU's are available to meet your unique requirements.
Features
- Functions including: Basic (BA), Metered Internet (MI), Advanced Monitored (AM), Switched (SW), Emergency Power Off (EM), Voltage Regulation (VR), and Automatic Transfer Switch (AT)
- Vertical and horizontal mounting options
- Power ranges including: Standard Power (0-4 kW), Mid-Range Power (4-10 kW), High Power (10-15 kW), and Ultra High Power (15+ kW)
- Rugged industrial construction and design
- EMI/RFI and Spike/Surge suppression available in most models.
- Products can be customized to fit your needs including military COTS and Data Center applications
- Accessories that let you customize your ePDU to fit your needs
Basic (BA) ePDU Products
![]() |
T982 Series
|
![]() |
TPC2104 Series
|
![]() |
TPC2105 Series
|
![]() |
TPC4100 Series
|
![]() |
PC2646 Series
|
![]() |
PC3365 & PC3365-3414
|
![]() |
T17 Series
|
![]() |
V70/V42 Series
V70 & V42 Series ePDU Spec Sheet |
![]() |
VPC2769 Series
|
![]() |
VPC1917 Series
|
![]() |
VPC2864 & VPC3106 Series
|
![]() |
V7H Series
|
![]() |
V55 Series
|
![]() |
LPC Products – UPS Extensions
|
Metered Internet (MI) ePDU Products
![]() |
T982 Series
|
![]() |
V70/V42 Series
V70
& V42 Series ePDU Spec Sheet |
![]() |
VPC2769 Series
|
![]() |
V55 Series
|
Switched (SW) ePDU Products
![]() |
IPC34xx Series
IPC34xx ePDU Spec Sheet |
![]() |
IPC36xx Series
IPC36xx ePDU Spec Sheet |
![]() |
IPV70/IPV42 Series
IPV70 & IPV42 Series ePDU Spec Sheet |
![]() |
IPC3400 Series
|
Automatic Transfer Switch (AT) ePDU Products
![]() |
TPC2234 Series
|
![]() |
T2235 Series
|
Emergency Power Off (EM) ePDU Products
![]() |
TPC115-10 Series
|
![]() |
PC125 Series and PC420 Series
|
![]() |
TPC2365 Series
|
![]() |
PC5585 Series
|
![]() |
TPC3474 Series
|
![]() |
PC2641 Series
|
![]() |
PC975 Series
|
![]() |
PC302-I Series
|
![]() |
PC2672
|
Voltage Regulation (VR) ePDU Products
![]() |
VR120-15 ePDU
|
![]() |
SDC1559 Series
|
ePDU Accessories
Special Notes and Features
*1 - Power (Amp) De-Rated Values
UL requires that a Breakers and PDU's be de-rated by 20% from their maximum value to allow for padding. Just like you wouldn't want to red-line your car all the time you should give yourself some head room when loading your PDU for events like start-up surges and other sudden demands. This will help ensure that you prevent nuisance circuit breaker tripping. To complicate matters a bit this only applies to North American standards, European ratings already have the de-rated amp ratings on their devices. Below is a table showing the input rating vs. the de-rated Output rating
| Input | De-Rated Value |
|---|---|
| 15A | 12A |
| 20A | 16A |
| 30A | 24A |
| 40A | 32A |
| 50A | 40A |
| 60A | 48A |