Rack Distribution and Monitoring (ePDU)
Enclosed Power Distribution Units (ePDU's) from Eaton offer many flexible ways to distribute power within your rack enclosure to your end equipment. All ePDU's are built with industrial-grade materials and offer features distinguish them from a “power strip” for your mission-critical backup power equipment. With a wide verity of inputs, outputs, power ranges, mounting options, and other features, there is most likely a product that fits your needs. Customized ePDU's are available to meet your unique requirements.
Features
- Functions including: Basic (BA), Metered Internet (MI), Advanced Monitored (AM), Switched (SW), Emergency Power Off (EM), Voltage Regulation (VR), and Automatic Transfer Switch (AT)
- Vertical and horizontal mounting options
- Power ranges including: Standard Power (0-4 kW), Mid-Range Power (4-10 kW), High Power (10-15 kW), and Ultra High Power (15+ kW)
- Rugged industrial construction and design
- EMI/RFI and Spike/Surge suppression available in most models.
- Products can be customized to fit your needs including military COTS and Data Center applications
- Accessories that let you customize your ePDU to fit your needs
Basic (BA) ePDU Products
![]() |
T982 Series
|
![]() |
TPC2104 Series
|
![]() |
TPC2105 Series
|
![]() |
TPC4100 Series
|
![]() |
PC2646 Series
|
![]() |
PC3365 & PC3365-3414
|
![]() |
T17 Series
|
![]() |
V70/V42 Series
V70 & V42 Series ePDU Spec Sheet |
![]() |
VPC2769 Series
|
![]() |
VPC1917 Series
|
![]() |
VPC2864 & VPC3106 Series
|
![]() |
V7H Series
|
![]() |
V55 Series
|
![]() |
LPC Products – UPS Extensions
|
Metered Internet (MI) ePDU Products
![]() |
T982 Series
|
![]() |
V70/V42 Series
V70
& V42 Series ePDU Spec Sheet |
![]() |
VPC2769 Series
|
![]() |
V55 Series
|
Switched (SW) ePDU Products
![]() |
IPC34xx Series
IPC34xx ePDU Spec Sheet |
![]() |
IPC36xx Series
IPC36xx ePDU Spec Sheet |
![]() |
IPV70/IPV42 Series
IPV70 & IPV42 Series ePDU Spec Sheet |
![]() |
IPC3400 Series
|
Automatic Transfer Switch (AT) ePDU Products
![]() |
TPC2234 Series
|
![]() |
T2235 Series
|
Emergency Power Off (EM) ePDU Products
![]() |
TPC115-10 Series
|
![]() |
PC125 Series and PC420 Series
|
![]() |
TPC2365 Series
|
![]() |
PC5585 Series
|
![]() |
TPC3474 Series
|
![]() |
PC2641 Series
|
![]() |
PC975 Series
|
![]() |
PC302-I Series
|
![]() |
PC2672
|
Voltage Regulation (VR) ePDU Products
![]() |
VR120-15 ePDU
|
![]() |
SDC1559 Series
|
ePDU Accessories
Special Notes and Features
*1 - Power (Amp) De-Rated Values
UL requires that a Breakers and PDU's be de-rated by 20% from their maximum value to allow for padding. Just like you wouldn't want to red-line your car all the time you should give yourself some head room when loading your PDU for events like start-up surges and other sudden demands. This will help ensure that you prevent nuisance circuit breaker tripping. To complicate matters a bit this only applies to North American standards, European ratings already have the de-rated amp ratings on their devices. Below is a table showing the input rating vs. the de-rated Output rating
| Input | De-Rated Value |
|---|---|
| 15A | 12A |
| 20A | 16A |
| 30A | 24A |
| 40A | 32A |
| 50A | 40A |
| 60A | 48A |