Eaton ePDU G3, Basic and Metered Rack Level ePDU

 

Eaton G3 ePDU

The new Eaton® ePDU® G3 platform provides best-in-class power distribution, enabling data center and information technology (IT) managers to effectively monitor and manage their rack environments. Featuring Eaton’s third-generation (G3) ePDU technology, G3 is easy to install and reduces operating costs while increasing reliability. With a host of unique and state-of-the-art features for Basic, Metered Input and Managed ePDUs, G3 sets the standard for power management in a wide range of key applications ranging from small/medium businesses to enterprise data centers.

Eaton's third-generation technology for power distribution

  • G3 Economical Basic, Metered Input, and Managed models
  • Local pixel LCD display for onsite management
  • 120V and lower kVA options
  • Outlet grip plug retention
  • Billing grade accuracy
  • Hot-swap eNMC module

View informational videos on the Eaton G3 ePDU Features

View G3 Basic and Metered brochure and Managed brochure.

 

Eaton ePDU G3 features and benefits

Key applications: Designed for the IT environment, G3 ePDU is available in a variety of configurations including both 120 and 200- 240 volt. Power distribution designed to properly connect servers, switches and other equipment.

Outlet grip plug retention: Eaton's new patented IEC outlet grip plugs into place with a lever actuated grip integrated into each outlet. This feature secures plugs, preventing accidental disconnect and eliminating the need for special power cords.

Billing grade accuracy: Monitor with higher accuracy with G3 one percent revenue-grade power monitoring.

Color coded outlet sections: G3 color-coded sections match corresponding circuit breakers, allowing for quick and easy identification of feeds and preventing unbalanced loading.

Advanced LCD pixel display: Simplify local setup and troubleshooting with the new ePDU G3 LCD display: view voltage, power, total input, and meters and alarm history. The convenient menu-driven display changes from blue to amber in alarm situations.

Hot-swap eNMC module: Increase uptime and improve serviceability. New hot-swap eNMC (ePDU Network Management and Control) module can be replaced without powering down the rack.

Low profile form factor: New G3 width for Basic and Metered ePDUs is optimized for side mounting, bringing zero interference to the rail space. Low-profile circuit breakers in some models reduce interference when mounted with outlets facing the rail (rack center).

High operating temperature: G3 ePDU models function in environments up to 140°F (60°C), reducing cooling costs. 

Daisy chain four units from one IP address: Eaton's new  daisy chain is available on all network connected G3 ePDUs, allowing for up to 4 ePDUs to share the same newtork connection and IP address. 

Ease of installation: Clip feet allow for a variety of mounting methods, mounting buttons are pre-installed, and optional side- mounting button locations are available for a 90-degree rotation in the rack.

To learn more, please visit: Eaton.com/ePDU3G or see the Model Selection Guide tab.

Network-Management

The advanced network capabilities of the G3 platform allow you to monitor multiple ePDUs through Eaton’s power monitoring solutions. In addition, G3 has built-in support for third-party data center infrastructure management (DCIM) solutions by using SNMP v3 to communicate securely to each ePDU.

Eaton ePDU G3 Network Management Guide Table

 

Environmental Monitoring

G3 ePDU environmental 
monitoring add on component EMP001


 

The optional environmental monitoring probe connects to the serial port and enables you to collect temperature and humidity readings in the rack environment to monitor environmental data remotely. You can also monitor the status of two contact closure devices, such as door switches.

G3 ePDU Basic and Metered model selection guide

Eaton ePDU G3 Selection Guide Table

G3 Basic ePDU

Catalog number Plug Breaker Max KW Output receptacles Dimensions (HxWxD, in.)*
EBA301-10 L15-20P (3) 20A 5.76 (30) C13, (6) C19
66.5 x 2.05 x 2.1
EBA311-10 L15-20P (3) 20A 5.76 (42) C13 69.5 x 2.05 x 2.1
EBA308-10 L21-20P None 5.76 (21) 5-20R, (6) L6-20R 66.5 x 2.05 x 2.1
EBA309-10 L21-20P None 5.76 (39) 5-20R 66.5 x 2.05 x 2.1
EBA302-10 L21-20P (3) 20A 5.76 (30) C13, (6) C19 66.5 x 2.05 x 2.1
EBA312-10 L21-20P (3) 20A 5.76 (42) C13 69.5 x 2.05 x 2.1
EBA303-10 L15-30P (3) 20A 8.64 (30) C13, (6) C19 66.5 x 2.05 x 2.1
EBA313-10 L15-30P (3) 20A 8.64 (42) C13 69.5 x 2.05 x 2.1
EBA310-10 L21-30P (3) 20A 8.64 (30) C13, (6) C19, (1) 5-20R 66.5 x 2.05 x 2.1
EBA304-10 L21-30P (3) 20A 8.64 (30) C13, (6) C19 66.5 x 2.05 x 2.1
EBA314-10 L21-30P (3) 20A 8.64 (42) C13 69.5 x 2.05 x 2.1
EBA305-06 CS8365 (3) 20A 12.48 (30) C13, (6) C19 66.5 x 2.05 x 2.1
EBA315-10 CS8365 (3) 20A 12.48 (42) C13 69.5 x 2.05 x 2.1
EBA300-06 CS8365   (2) 20A, (1) 30A 
14.4   (24) C13, (4) C19, (2) L6-30P 
66.5 x 2.05 x 2.1
EBA306-06 CS8365 (6) 20A 14.4 (21) C13, (12) C19 66.5 x 2.05 x 2.1
EBA307-06   IEC60309 460P9 
(6) 20A 17.3 (21) C13, (12) C19 66.5 x 2.05 x 2.1


G3 Metered ePDU

Catalog number Plug Breaker Max KW Output receptacles Dimensions (HxWxD, in.)*
EMI100-10 5-15P None 1.44 (24) 5-15R 66.5 x 2.05 x 2.1
EMI101-10 L5-20P (5-20P adapter) None
1.92 (24) 5-15R 66.5 x 2.05 x 2.1
EMI102-10 L5-30P (2) 20A 2.88 (24) 5-15R 66.5 x 2.05 x 2.1
EMI103-10 C20 (L6-20 adapter) None 3.84 (18) C13, (2) C19 35.5 x 2.05 x 2.1
EMI105-06 IEC60309 360P9 (3) 20A 11.5 (30) C13, (6) C19 66.5 x 2.05 x 2.1
EMI200-10 L14-30P (2) 20A 5.76 (20) C13, (6) C19, (8) 5-20R 66.5 x 2.05 x 2.1
EMI301-10 L15-20P (3) 20A 5.76 (30) C13, (6) C19 66.5 x 2.05 x 2.1
EMI311-10 L15-20P (3) 20A 5.76 (42) C13 69.5 x 2.05 x 2.1
EMI308-10 L21-20P None 5.76 (21) 5-20R, (6) L6-20R 66.5 x 2.05 x 2.1
EMI309-10 L21-20P None
5.76 (39) 5-20R 66.5 x 2.05 x 2.1
EMI318-10 L21-20P None
5.76 (30) C13, (6) C19, (3) 5-20R 66.5 x 2.05 x 2.1
EMI302-10 L21-20P (3) 20A 5.76 (30) C13, (6) C19 66.5 x 2.05 x 2.1
EMI312-10 L21-20P (3) 20A 5.76 (42) C13 69.5 x 2.05 x 2.1
EMI104-10 L6-30P (2) 20A 5.76 (36) C13, (6) C19 66.5 x 2.05 x 2.1
EMI303-10 L15-30P (3) 20A 8.64 (30) C13, (6) C19 66.5 x 2.05 x 2.1
EMI313-10 L15-30P   (3) 20A  8.64 (42) C13 69.5 x 2.05 x 2.1
EMI310-10 L21-30P (3) 20A 8.64 (30) C13, (6) C19, (1) 5-20R 66.5 x 2.05 x 2.1
EMI304-10 L21-30P (3) 20A 8.64 (30) C13, (6) C19 66.5 x 2.05 x 2.1
EMI314-10 L21-30P (3) 20A 8.64 (42) C13 69.5 x 2.05 x 2.1
EMI305-06 CS8365 (3) 20A 12.48 (30) C13, (6) C19 66.5 x 2.05 x 2.1
EMI315-10 CS8365 (3) 20A 12.48 (42) C13 69.5 x 2.05 x 2.1
EMI300-06 CS8365  (2) 20A, (1) 30A
14.4 (24) C13, (4) C19, (2) L6-30R 66.5 x 2.05 x 2.1
EMI316-06 CS8365 (6) 20A 14.4 (9) C13, (12) C19 66.5 x 2.05 x 2.1
EMI317-06   IEC60309 460P9 
(6) 20A 17.3 (9) C13, (12) C19 66.5 x 2.05 x 2.1
EMI319-10 IEC60309 532P6 (6) 20A 11.5 (24) C13, (6) C19 66.5 x 2.05 x 2.1
EMI320-10 IEC60309 516P6 None 17.3 (30) C13, (6) C19 66.5 x 2.05 x 2.1


G3 Managed ePDU

Catalog number Plug Breaker Max KW Output receptacles Dimensions (HxWxD, in.)*
EMA106-10 L6-20P None 3.84 (7) C13 Outlet grip, (1) C19 Outlet grip 35.5 X 2.05 X 2.1
EMA107-10 L6-30P (2) 20A 5.76 (20) C13 Outlet grip, (4) C19 Outlet grip 66.5 x 2.05 x 2.1
EMA108-10 L5-30P (2) 20A 2.88 (24) 5-20R 66.5 X 2.05 X 2.56
EMA324-10 L15-20P (3) 20A 5.76 (18) C13 Outlet grip, (6) C19 Outlet grip 66.5 X 2.05 X 2.56
EMA325-10 L21-20P (3) 20A 5.76 (18) C13 Outlet grip, (6) C19 Outlet grip 66.5 X 2.05 X 2.56
EMA326-10 L15-30P (3) 20A 8.64 (18) C13 Outlet grip, (6) C19 Outlet grip 66.5 X 2.05 X 2.56
EMA327-10 L21-30P (3) 20A 8.64 (18) C13 Outlet grip, (6) C19 Outlet grip 66.5 X 2.05 X 2.56
EMA328-10 CS8365 (3) 20A 12.48 (18) C13 Outlet grip, (6) C19 Outlet grip 66.5 X 2.05 X 2.56
EMA329-06 CS8365 (6) 20A 14.4 (12) C13 Outlet grip, (12) C19 Outlet grip 66.5 X 2.05 X 2.56
EMA330-06 IEC309 460P9W (6) 20A 17.3 (12) C13 Outlet grip, (12) C19 Outlet grip 66.5 X 2.05 X 2.56