  • Arrgh’s Mark 5 is designed to detect the presence of Hydrogen before it reaches dangerous levels, and detect smoke, inside a room or enclosure. The unit contains output contacts for exhaust fans and alarms.
  • Arrgh’s Mark IV hydrogen detector is designed to detect the presence of hydrogen before it reaches dangerous levels inside a room or enclosure. The unit contains output contacts for exhaust fans and alarms.
  • The mimic panel allows a user to duplicate the LED indicators, the audible warning, and push to test function from a location up to 1000 feet from the actual H2 sensor.
  • Sensors and probes to be used with Eaton network cards or metered/managed PDU's
  • NOTE: This item is obsolete and has been replaced by the Eaton Tripp Lite Basic PDU. Please contact us for more information. Eaton Basic rack PDU, 0U, L5-30P input, 2.88 kW max, 100-127V, 24A, 15 ft cord, Single-phase, Outlets: (24) 5-20R
  • NOTE: This item is obsolete and has been replaced by the Eaton 9PX UPS and the Eaton 9SX UPS. Please contact us for more information. Manufactured specifically for harsh environments outside the office, industrial designed UPS equipment is crafted and tested to meet the unpredictable demands of field operations.
  • The Eaton® ePDU® G3 rack mounted power distribution units (PDUs) provide best-in-class power distribution to information technology (IT) equipment within a rack, enabling data center and IT managers to simplify installation, enhance operation and maximize control of their environment. We offer a tiered portfolio of rack PDUs in multiple form factors with capabilities ranging from basic power distribution to advanced power management and precision control designed to save time, save money and reduce risk.
  • With its universal input, dynamic C39 outlets and global approval, Eaton’s G3 universal input PDU (G3 UPDU) is a single solution equipped to meet the most diverse data center rack power needs. This fully managed PDU accommodates single- and 3-phase power in 120V and 230V environments, as well as equipment with a variety of connectors and power demands. The G3 UPDU boasts all the sophisticated management capabilities you expect from an Eaton PDU and can be easily deployed into a single data center or a global project across multiple locations—saving time, reducing costs and simplifying power management.
  • Eaton Managed ePDUs allow you to monitor and control critical factors such as voltage, current and power factor. This level of information allows you to make the right decision when it comes to energy consumption in your data center. Integrated with Eaton's management software, you can control these units from any computer on the network server.
  • NOTE: This item is obsolete. Please contact us for a replacement model.
    • 1,920VA to 3,840VA
    • Standard 1U 19" Rack Mount
    • Individually control (8) Outlets via Serial or Ethernet connections
    • Built-in web interface lets you control the outlets from a standard browser
    • Connect up to (10) units together for control of up to (80) outlets from a single point via RS485 serial bus
    • Easy-to-write programs to control the unit via Serial or Telnet commands
    • Input 1-Phase 120VAC or 100-240VAC Models
    • (8) Outlets of either 5-15, C13, or (4) 5-20 + (4) 5-15
    • Optional Cable Support Tray System or Vertical Mount Brackets
    • UL489 List Circuit Breaker
    • EMI/RFI filtering and Spike/Surge Suppression
  • NOTE: This item is obsolete. Please contact us for a replacement model.
    • 1,920VA to 5,760VA
    • Standard 1U 19" Rack Mount
    • Individually control (8) Outlets via Serial or Ethernet connections
    • Built-in web interface lets you control the outlets from a standard browser
    • Setup up to (10) users with advanced security rights
    • (8) C13 or 5-15 Outlets
    • Spike/Surge Suppression
  • Brightlayer Power delivers real-time insights into the condition, demand and energy usage of your electrical systems—so you can make smarter, faster decisions. With intuitive dashboards, proactive alerts and continuous monitoring, it helps your team reduce downtime, optimize energy use and strengthen safety and resiliency across your entire operation.
  • NOTE: This item is obsolete and has been replaced by the Eaton Brightlayer Power. Please contact us for more information. Eaton's Intelligent Power Manager (IPM) software provides the tools needed to monitor and manage power devices in your physical or virtual environment. This innovative software solution ensures system uptime and data integrity by allowing you to remotely monitor, manage and control UPSs and other devices on your network. IPM provides a solution that is easy to use and maintains business continuity.
  • NOTE: This item is obsolete. Please contact us for a replacement model.
    • 1,440VA to 5,760VA
    • Vertical Rack Mounted either 42" or 70" (38" or 66" with alternate mounting)
    • Many input options including C20, 5-15, 5-20, L5-30, L6-30, L21-20, and L15-20 Plugs
    • Between (8) and (24) C13 or 5-15 Outlets
    • Individually control (8) Outlets via Serial or Ethernet connections
    • Built-in web interface lets you control the outlets from a standard browser
    • Setup up to (10) users with advanced security rights
    • Current meter per section and voltage readings
    • Local current meter display
    • Connect optional Temperature and Humidity probes to the unit
    • Email alerts and events
    • SNMP Control for easy network administration or creating programs to control the unit
  • EC60320 C13 and C19 cables are commonly used on electronic equipment such as computers, monitors, and servers to ensure international compatibility across different countries’ standards. For example, the most common cable is the C13, which is used to power standard PCs and monitors. With today’s high-power applications, the C19 connector is becoming more common for use with servers and power distribution units (ePDU). Each connector has two part numbers. The female is always an odd number (C13) and the male is always the next even number (C14). Most standard PCs have a C14 male inlet and in the US use a C13 (female) to standard 5-15 plug cord-set. Features:
    • Designed to allow equipment to be plugged into different outlets
    • International design allows for use in multiple countries
    • C13/C14 Cables 100-250VAC, 10A 47-63 HZ
    • C19/C20 Cables 100-250VAC, 16A 47-63 HZ
  • NOTE: This item is obsolete. Please contact us for a replacement model.
    • 1,440VA to 5,760VA
    • Standard 2U 19" Rack Mount
    • (12) Outlets of either 5-15, 5-20, or 6-15
    • Input Options: 5-15, 5-20, L5-30 120V, or L6-30 240V
    • 3-Pin Remote Control EPO Interface (Latching –LT or non-latching)
    • Option Multiple Time Delay on power-up (MTD)
    • EMI/RFI filtering and Spike/Surge Suppression
    • Connect multiple units to a single Remote Control Panel (RCP)
  • NOTE: This item is obsolete. Please contact us for a replacement model.
    • 8,640VA
    • Input: 120/208VAC 3-Phase WYE, 30A per phase via L21-30 Plug
    • Output: (14) 5-20 outlets, (2) or which are always-on convince outlets
    • 3-Pin Remote Control EPO Interface (Latching LT or non-latching)
    • Option Multiple Time Delay on power-up (MTD)
    • EMI/RFI filtering and Spike/Surge Suppression
    • Connect multiple units to a single Remote Control Panel (RCP)
  • NOTE: This item is obsolete. Please contact us for a replacement model.
    • 8,640VA
    • Input: 120/208VAC 3-Phase, 30A, 50-60HZ via L21-30 Plug
    • Standard 2U 19" Rack Mount
    • (18) Standard 5-15 outlets or (18) 20A 5-20 Outlets (T Style)
    • Main 3-Pole 30A Breaker with  (3) 2-Pole UL489 Branch Listed Circuit Breakers, one per phase (15A or 20A)
    • EMI/RFI Filtering and Spike/Surge Suppression
    • Rugged 16 AWG zinc-plated chassis great in harsh environments
  • NOTE: This item is obsolete. Please contact us for a replacement model.
    • 8,640VA in North America or 16,560VA in Europe
    • Input: 120/208VAC or 230/400VAC
    • IEC60309 32A 3-Phase 5-Wire Plug; use Cable Adapter/Extension for L21-30P or IEC60309 32A
    • Output: (4) C19 outlets, (12) C13 Outlets, and (1) IEC60309 32A 3-Phase 5-Wire
    • Latching 3-Pin Remote Control Interface
    • EMI/RFI Filtering and Spike/Surge Suppression
    • Connect multiple units to a single Remote Control Panel (RCP)
  • NOTE: This item is obsolete. Please contact us for a replacement model.
    • 8,640VA in North America or 11,040VA in Europe
    • Input 120/208V or 230/400VAC via 5-position Terminal Block
    • Input Power Cables with L21-30 or IEC60309 connector for Europe
    • Output: (14) C13 outlets, (2) are convince always-on outlets
    • 3-Pin Remote Control EPO Interface (Latching LT or non-latching)
    • Option Multiple Time Delay on power-up (MTD)
    • EMI/RFI Filtering and Spike/Surge Suppression
    • Connect multiple units to a single Remote Control Panel (RCP)
  • NOTE: This item is obsolete. Please contact us for a replacement model.
    • 8,640VA North America or 11,040VA International Models
    • 3-Phase 120/208VAC 30A or 230/400VAC 20A inputs
    • Standard 2U 19" Rack Mount
    • Spike/Surge Suppression
    • Cable Restraint and Management Tray included
    • (24) C13 outlets @ 120 or 230VAC (8) Per Phase
  • NOTE: This item is obsolete. Please contact us for a replacement model.
    • 3,840VA to 5,760VA
    • Standard 2U 19" Rack Mount
    • (14) C13 outlets, (2) of which are convince outlets (always on)
    • Input: Terminal Blocks for various 20A or 30A cables
    • 3-Pin Remote Control EPO Interface (Latching LT or non-latching)
    • Option Multiple Time Delay on power-up (MTD)
    • EMI/RFI filtering and Spike/Surge Suppression
    • Connect multiple units to a single Remote Control Panel (RCP)
    • NOTE: This item is obsolete and has been replaced by the Eaton PC975-R. Please contact us for more information.
     
    • 8,640VA
    • Input: 120/208VAC 3-Phase WYE, 30A per phase via L21-30 Plug
    • Output: (8) 5-20 outlets and (3) twist-lock outlets of various options including L6-20, L6-30, and L21-30
    • 3-Pin Remote Control EPO Interface (Latching LT or non-latching)
    • Option Multiple Time Delay on power up (MTD)
    • EMI/RFI filtering and Spike/Surge Suppression
    • Connect multiple units to a single Remote Control Panel (RCP)
  • Eaton REPO rack PDU, 2U IN: L21-30 24A 3P OUT: 8X5-20R, 3XL6-20R, MTD, STANDARD

    Remote emergency power off (REPO) rack PDUs enable immediate and complete power off control from one button. These PDUs are hardwired and the power off switch can be housed anywhere in the data center for quick and easy access, should the need for immediate shutdown arise.

About HM Cragg

HM Cragg has been providing quality backup power solutions since 1968 as a manufacturer’s representative and distributor of uninterruptible power systems, generators, power electronics, backup battery applications, and other complementary products. Headquartered in Edina, MN, we maintain a national presence with, four distribution centers (Minnesota, Virginia, Texas and Nevada), and sales personnel located across the country. As an employee-owned company, our “owners” represent the values of the company – honesty, trust, integrity, ethics, and knowledge. This translates into a customer experience that’s a “WOW" or we make it right!